public sealed class EmulatorConfiguration
Namespace: SharpMeter.Emulator
Properties
| Name | Description |
|---|---|
FirmwareVersion |
Gets or sets the firmware version [major, minor, build, patch]. |
HardwareRevision |
Gets or sets the hardware revision number. |
HardwareVersion |
Gets or sets the hardware version number. |
Manufacturer |
Gets or sets the emulated manufacturer name (4 chars, per ST1). |
MaxPackets |
Gets or sets the maximum number of packets. |
MaxPacketSize |
Gets or sets the maximum packet size. |
Mode |
Gets or sets the meter mode. |
Model |
Gets or sets the meter model type. |
ModelString |
Gets or sets the emulated model string (8 chars, per ST1). |
Password |
Gets or sets the security password (up to 20 bytes). Empty means no authentication required. |
ProcedureAccessLevel |
Gets or sets the minimum access level required for procedure execution. |
ReadAccessLevel |
Gets or sets the minimum access level required for table reads. |
SerialNumber |
Gets or sets the emulated serial number (16 chars, per ST1). |
Target |
Gets or sets the target utility type. |
Upgrades |
Gets or sets the active softswitch upgrades. |
WriteAccessLevel |
Gets or sets the minimum access level required for table writes. |
FirmwareVersion
byte[] EmulatorConfiguration.FirmwareVersion { get; set; }
Gets or sets the firmware version [major, minor, build, patch].
HardwareRevision
byte EmulatorConfiguration.HardwareRevision { get; set; }
Gets or sets the hardware revision number.
HardwareVersion
byte EmulatorConfiguration.HardwareVersion { get; set; }
Gets or sets the hardware version number.
Manufacturer
string EmulatorConfiguration.Manufacturer { get; set; }
Gets or sets the emulated manufacturer name (4 chars, per ST1).
MaxPackets
byte EmulatorConfiguration.MaxPackets { get; set; }
Gets or sets the maximum number of packets.
MaxPacketSize
ushort EmulatorConfiguration.MaxPacketSize { get; set; }
Gets or sets the maximum packet size.
Mode
MeterMode EmulatorConfiguration.Mode { get; set; }
Gets or sets the meter mode.
Model
MeterModel EmulatorConfiguration.Model { get; set; }
Gets or sets the meter model type.
ModelString
string EmulatorConfiguration.ModelString { get; set; }
Gets or sets the emulated model string (8 chars, per ST1).
Password
byte[] EmulatorConfiguration.Password { get; set; }
Gets or sets the security password (up to 20 bytes). Empty means no authentication required.
ProcedureAccessLevel
AccessLevel EmulatorConfiguration.ProcedureAccessLevel { get; set; }
Gets or sets the minimum access level required for procedure execution.
ReadAccessLevel
AccessLevel EmulatorConfiguration.ReadAccessLevel { get; set; }
Gets or sets the minimum access level required for table reads.
SerialNumber
string EmulatorConfiguration.SerialNumber { get; set; }
Gets or sets the emulated serial number (16 chars, per ST1).
Target
MeterTarget EmulatorConfiguration.Target { get; set; }
Gets or sets the target utility type.
Upgrades
SoftswitchUpgrade EmulatorConfiguration.Upgrades { get; set; }
Gets or sets the active softswitch upgrades.
WriteAccessLevel
AccessLevel EmulatorConfiguration.WriteAccessLevel { get; set; }
Gets or sets the minimum access level required for table writes.
View Source
/// <summary>
/// Configuration for the PSEM meter emulator.
/// </summary>
public sealed class EmulatorConfiguration
{
#region Identity
/// <summary>Gets or sets the emulated manufacturer name (4 chars, per ST1).</summary>
public string Manufacturer { get; set; } = "MOKA";
/// <summary>Gets or sets the emulated model string (8 chars, per ST1).</summary>
public string ModelString { get; set; } = "EMULATOR";
/// <summary>Gets or sets the emulated serial number (16 chars, per ST1).</summary>
public string SerialNumber { get; set; } = "0000000000000001";
/// <summary>Gets or sets the firmware version [major, minor, build, patch].</summary>
[SuppressMessage("Performance", "CA1819:Properties should not return arrays", Justification = "Configuration DTO used for testing; array simplifies initialization.")]
public byte[] FirmwareVersion { get; set; } = [1, 0, 0, 0];
/// <summary>Gets or sets the hardware version number.</summary>
public byte HardwareVersion { get; set; } = 1;
/// <summary>Gets or sets the hardware revision number.</summary>
public byte HardwareRevision { get; set; }
#endregion
#region Security
/// <summary>Gets or sets the security password (up to 20 bytes). Empty means no authentication required.</summary>
[SuppressMessage("Performance", "CA1819:Properties should not return arrays", Justification = "Configuration DTO used for testing; array simplifies binary data handling.")]
public byte[] Password { get; set; } = [];
/// <summary>Gets or sets the minimum access level required for table reads.</summary>
public AccessLevel ReadAccessLevel { get; set; } = AccessLevel.NoAccess;
/// <summary>Gets or sets the minimum access level required for table writes.</summary>
public AccessLevel WriteAccessLevel { get; set; } = AccessLevel.Reader;
/// <summary>Gets or sets the minimum access level required for procedure execution.</summary>
public AccessLevel ProcedureAccessLevel { get; set; } = AccessLevel.Master;
#endregion
#region Meter Configuration
/// <summary>Gets or sets the target utility type.</summary>
public MeterTarget Target { get; set; } = MeterTarget.Electric;
/// <summary>Gets or sets the meter model type.</summary>
public MeterModel Model { get; set; } = MeterModel.Generic;
/// <summary>Gets or sets the meter mode.</summary>
public MeterMode Mode { get; set; } = MeterMode.DemandOnly;
/// <summary>Gets or sets the active softswitch upgrades.</summary>
public SoftswitchUpgrade Upgrades { get; set; } = SoftswitchUpgrade.None;
/// <summary>Gets or sets the maximum packet size.</summary>
public ushort MaxPacketSize { get; set; } = 128;
/// <summary>Gets or sets the maximum number of packets.</summary>
public byte MaxPackets { get; set; } = 254;